1
SECTION 3
HIGH RESOLUTION
SIGNAL CONDITIONING ADCs
Sigma-Delta ADCs
High Resolution, Low Frequency
Measurement ADCs
2
SECTION 3
HIGH RESOLUTION SIGNAL
CONDITIONING ADCs
Walt Kester, James Bryant, Joe Buxton
The trend in ADCs and DACs is toward higher speeds and higher resolutions at
reduced power levels. Modern data converters generally operate on ±5V (dual
supply) or +5V (single supply). There are now a few converters which operate on a
single +3V supply. This trend has created a number of design and applications
problems which were much less important in earlier data converters, where ±15V
supplies were the standard.
Lower supply voltages imply smaller input voltage ranges, and hence more
susceptibility to noise from all potential sources: power supplies, references, digital
signals, EMI/RFI, and probably most important, improper layout, grounding, and
decoupling techniques. Single-supply ADCs often have an input range which is not
referenced to ground. Finding compatible single-supply drive amplifiers and dealing
with level shifting of the input signal in direct-coupled applications also becomes a
challenge.
In spite of these issues, components are now available which allow extremely high
resolutions at low supply voltages and low power. This section discusses the
applications problems associated with such components and shows techniques for
successfully designing them into systems.
LOW POWER, LOW VOLTAGE ADC DESIGN ISSUES
Low Power ADCs typically run on 5V, +5V, +5/+3V, or +3V
Lower Signal Swings Increase Sensitivity to All Types of Noise
(Device, Power Supply, Logic, etc.)
Device Noise Increases at Low Quiescent Currents
Bandwidth Suffers as Supply Current Drops
Input Common-Mode Range May be Limited
Selection of Zero-Volt Input/Output Amplifiers is Limited
Auto-Calibration Modes Highly Desirable at High Resolutions
Figure 3.1
3
SIGMA-DELTA ADCS
(COURTESY OF JAMES M. BRYANT)
Because Sigma-Delta is such an important and popular architecture for high
resolution (16 to 24 bits) ADCs, the section begins with a basic description of this
type of converter.
Sigma-Delta Analog-Digital Converters have been known for nearly thirty years, but
only recently has the technology (high-density digital VLSI) existed to manufacture
them as inexpensive monolithic integrated circuits. They are now used in many
applications where a low-cost, low-bandwidth, low-power, high-resolution ADC is
required.
There have been innumerable descriptions of the architecture and theory of Sigma-
Delta ADCs, but most commence with a maze of integrals and deteriorate from
there. In the Applications Department at Analog Devices, we frequently encounter
engineers who do not understand the theory of operation of Sigma-Delta ADCs and
are convinced, from study of a typical published article, that it is too complex to
comprehend easily.
There is nothing particularly difficult to understand about Sigma-Delta ADCs, as
long as you avoid the detailed mathematics, and this section has been written in an
attempt to clarify the subject. A Sigma-Delta ADC contains very simple analog
electronics (a comparator, a switch, and one or more integrators and analog
summing circuits), and quite complex digital computational circuitry. This circuitry
consists of a digital signal processor (DSP) which acts as a filter (generally, but not
invariably, a low pass filter). It is not necessary to know precisely how the filter
works to appreciate what it does. To understand how a Sigma-Delta ADC works one
should be familiar with the concepts of over-sampling, noise shaping, digital
filtering. and decimation.
SIGMA-DELTA ( - ) ADCs
Sigma-Delta ADCs are low-cost and have high resolution, excellent
DNL, low-power, although limited input bandwidth
A - ADC is Simple
The Mathematics, however is Complex
This section Concentrates on What Actually Happens!
Figure 3.2
4
SIGMA-DELTA ADC KEY CONCEPTS
Oversampling
Noise Shaping
Digital Filtering
Decimation
Figure 3.3
An ADC is a circuit whose digital output is proportional to the ratio of its analog
input to its analog reference. Often, but by no means always, the scaling factor
between the analog reference and the analog signal is unity, so the digital signal
represents the normalized ratio of the two.
Figure 3.4 shows the transfer characteristic of an ideal 3-bit unipolar ADC. The
input to an ADC is analog and is not quantized, but its output is quantized. The
transfer characteristic therefore consists of eight horizontal steps (when considering
the offset, gain and linearity of an ADC we consider the line joining the midpoints of
these steps).
TRANSFER CHARACTERISTIC OF
AN IDEAL 3-BIT UNIPOLAR ADC
Figure 3.4
Digital full scale (all "1"s) corresponds to 1 LSB below the analog full scale (the
reference or some multiple thereof). This is because, as mentioned above, the digital
code represents the normalized ratio of the analog signal to the reference, and if this
were unity, the digital code would be all "0"s and "1" in the bit above the MSB.
5
The (ideal) ADC transitions take place at _ LSB above zero and thereafter every
LSB, until 1_ LSB below analog full scale. Since the analog input to an ADC can
take any value, but the digital output is quantized, there may be a difference of up to
_ LSB between the actual analog input and the exact value of the digital output.
This is known as the quantization error or quantization uncertainty. In AC
(sampling) applications, this quantization error gives rise to quantization noise.
If we apply a fixed input to an ideal ADC, we will always obtain the same output,
and the resolution will be limited by the quantization error.
Suppose, however, that we add some AC (dither) to the fixed signal, take a large
number of samples, and prepare a histogram of the results. We will obtain
something like the result in Figure 3.5. If we calculate the mean value of a large
number of samples, we will find that we can measure the fixed signal with greater
resolution than that of the ADC we are using. This procedure is known as
over-sampling.
OVERSAMPLING WITH DITHER ADDED TO INPUT
Figure 3.5
The AC (dither) that we add may be a sine-wave, a tri-wave, or Gaussian noise (but
not a square wave) and, with some types of sampling ADCs (including Sigma-Delta
ADCs), an external dither signal is unnecessary, since the ADC generates its own.
Analysis of the effects of differing dither waveforms and amplitudes is complex and,
for the purposes of this section, unnecessary. What we do need to know is that with
the simple over-sampling described here, the number of samples must be doubled for
each _bit of increase in effective resolution.
If, instead of a fixed DC signal, the signal that we are over-sampling is an AC signal,
then it is not necessary to add a dither signal to it in order to over-sample, since the
signal is moving anyway. (If the AC signal is a single tone harmonically related to
the sampling frequency, dither may be necessary, but this is a special case.)
Let us consider the technique of over-sampling with an analysis in the frequency
domain. Where a DC conversion has a quantization error of up to _ LSB, a sampled
data system has quantization noise. As we have already seen, a perfect classical
6
N-bit sampling ADC has an rms quantization noise of q/(sqrt 12) uniformly
distributed within the Nyquist band of DC to fs/2 (where q is the value of an LSB
and fs is the sampling rate). Therefore, its SNR with a full-scale sinewave input will
be (6.02N + 1.76) dB. If the ADC is less than perfect, and its noise is greater than its
theoretical minimum quantization noise, then its effective resolution will be less
than N -bits. Its ac tu al r eso lutio n ( o fte n k n o wn as its E f fe c tiv e Nu m ber o f B its or
E N OB ) will be de f ine d by
ENOB SNR dBdB= ? 1766 02 .. .
SAMPLING ADC QUANTIZATION NOISE
Figure 3.6
If we choose a much higher sampling rate, the quantization noise is distributed over
a wider bandwidth as shown in Figure 3.7. If we then apply a digital low pass filter
(LPF) to the output, we remove much of the quantization noise, but do not affect the
wanted signal - so the ENOB is improved. We have accomplished a high resolution
A/D conversion with a low resolution ADC.
7
OVERSAMPLING FOLLOWED BY DIGITAL FILTERING
AND DECIMATION IMPROVES SNR AND ENOB
Figure 3.7
Since the bandwidth is reduced by the digital output filter, the output data rate may
be lower than the original sampling rate and still satisfy the Nyquist criterion. This
may be achieved by passing every Mth result to the output and discarding the
remainder. The process is known as "decimation" by a factor of M. Despite the
origins of the term (decem is Latin for ten), M can have any integer value, provided
that the output data rate is more than twice the signal bandwidth. Decimation does
not cause any loss of information (see Figure 3.8).
DECIMATION
Figure 3.8
8
If we simply use over-sampling to improve resolution, we must over-sample by a
factor of 2^2N to obtain an N-bit increase in resolution. The Sigma-Delta converter
does not need such a high over-sampling ratio because it not only limits the signal
passband, but also shapes the quantization noise so that most of it falls outside this
passband.
If we take a 1-bit ADC (generally known as a comparator), drive it with the output of
an integrator, and feed the integrator with an input signal summed with the output
of a 1-bit DAC fed from the ADC output, we have a first-order Sigma-Delta
modulator as shown in Figure 3.9. Add a digital low pass filter (LPF) and decimator
at the digital output, and we have a Sigma-Delta ADC: the Sigma-Delta modulator
shapes the quantization noise so that it lies above the passband of the digital output
filter, and the ENOB is therefore much larger than would otherwise be expected
from the over-sampling ratio.
FIRST ORDER SIGMA-DELTA ADC
Figure 3.9
By using more than one integration and summing stage in the Sigma-Delta
modulator, we can achieve higher orders of quantization noise shaping and even
better ENOB for a given over-sampling ratio as is shown in Figure 3.10 for both a
first and second-order Sigma-Delta modulator. The block diagram for the second-
order Sigma-Delta modulator is shown in Figure 3.11. Third, and higher, order
Sigma-Delta ADCs were once thought to be potentially unstable at some values of
input - recent analyses using finite rather than infinite gains in the comparator have
shown that this is not necessarily so, but even if instability does start to occur, it is
not important, since the DSP in the digital filter and decimator can be made to
recognize incipient instability and react to prevent it.
9
SIGMA-DELTA MODULATORS
SHAPE QUANTIZATION NOISE
Figure 3.10
SECOND-ORDER SIGMA-DELTA ADC
Figure 3.11
Figure 3.12 shows the relationship between the order of the Sigma-Delta modulator
and the amount of over-sampling necessary to achieve a particular SNR.
1
0
SNR VERSUS OVERSAMPLING RATIO
FOR FIRST, SECOND, AND THIRD-ORDER LOOPS
Figure 3.12
The Sigma-Delta ADCs that we have described so far contain integrators, which are
low pass filters, whose passband extends from DC. Thus, their quantization noise is
pushed up in frequency. At present, all commercially available Sigma-Delta ADCs
are of this type (although some which are intended for use in audio or
telecommunications applications contain bandpass rather than lowpass digital
filters to eliminate any system DC offsets). Sigma-Delta ADCs are available with
resolutions up to 24-bits for DC measurement applications (AD7710, AD7711,
AD7712, AD7713, AD7714), and with resolutions of 18-bits for high quality digital
audio applications (AD1879).
But there is no particular reason why the filters of the Sigma-Delta modulator
should be LPFs, except that traditionally ADCs have been thought of as being
baseband devices, and that integrators are somewhat easier to construct than
bandpass filters. If we replace the integrators in a Sigma-Delta ADC with bandpass
filters (BPFs), the quantization noise is moved up and down in frequency to leave a
virtually noise-free region in the pass-band (see Reference 1). If the digital filter is
then programmed to have its pass-band in this region, we have a Sigma-Delta ADC
with a bandpass, rather than a low pass characteristic (see Figure 3.13). Although
studies of this architecture are in their infancy, such ADCs would seem to be ideally
suited for use in digital radio receivers, medical ultrasound, and a number of other
applications.
1
1
REPLACING INTEGRATORS WITH RESONATORS
GIVES A BANDPASS SIGMA-DELTA ADC
Figure 3.13
A Sigma-Delta ADC works by over-sampling, where simple analog filters in the
Sigma-Delta modulator shape the quantization noise so that the SNR in the
bandwidth of interest is much lower than would otherwise be the case, and by using
high performance digital filters and decimation to eliminate noise outside the
required passband. Because the analog circuitry is so simple and undemanding, it
may be built with the same digital VLSI process that is used to fabricate the DSP
circuitry of the digital filter. Because the basic ADC is 1-bit (a comparator), the
technique is inherently linear.
Although the detailed analysis of Sigma-Delta ADCs involves quite complex
mathematics, their basic design can be understood without the necessity of any
mathematics at all. For further discussion on Sigma-Delta ADCs, refer to References
2 and 3.
SIGMA-DELTA SUMMARY
Linearity is Inherently Excellent
High Resolutions (16 - 24 Bits)
Ideal for Mixed-Signal IC Processes, no Trimming
No SHA Required
Charge Injection at Input Presents Drive Problems
Upper Sampling Rate Currently Limits Applications to
Measurement, Voiceband, and Audio, but Bandpass
Sigma-Delta Techniques Will Change This
Analog Multiplexing Applications are Limited by
Internal Filter Settling Time. Consider One Sigma-
Delta ADC per Channel.
Figure 3.14
1
2
HIGH RESOLUTION, LOW-FREQUENCY MEASUREMENT
ADCS
The AD7710, AD7711, AD7712, AD7713, and AD7714 are members of a family of
sigma-delta converters designed for high accuracy, low frequency measurements.
They have no missing codes at 24-bits and useful resolution of up to 21.5-bits
(AD7710, AD7711, AD7712, and AD7713), and 22.5 bits (AD7714). They all use
similar sigma-delta cores, and their main differences are in their analog inputs,
which are optimized for different transducers. The AD7714 is the newest member of
the family and is fully specified for either +5V (AD7714-5) or +3V (AD7714-3)
operation.
The digital filter in the sigma-delta core may be programmed by the user for output
update rates between 10Hz and 1kHz (AD7710, AD7711, AD7712), 2Hz and 200Hz
(AD7713), and 2Hz and 1kHz (AD7714). The effective resolution of these ADCs is
inversely proportional to the bandwidth. For example, for 22.5-bits of effective
resolution, the output update rate of the AD7714 cannot exceed 10Hz. The AD771X
family is ideal for such sensor applications as those shown in Figure 3.15.
SIGNAL CONDITIONING, TRANSDUCER INPUT ADCs
THE AD7710, AD7711, AD7712, AD7713, AD7714
Ultra-High Resolution Measurement Systems
Implemented Using Conversion
Ideal for Applications Such As:
Weigh Scales
RTDs
Thermocouples
Strain Gauges
Process Control
Smart Transmitters
Medical
Figure 3.15
The AD771X family has a high level of integration which simplifies the design of
data acquisition systems. For example, the AD7710 (Figures 3.16 and 3.17) has two
high impedance differential inputs that can be interfaced directly to many different
sensors, including resistive bridges. The two inputs are selected by the internal
multiplexer, which passes the signal to a programmable gain amplifier (PGA). The
PGA has a digitally programmable gain range of 1 to 128 to accommodate a wide
range of signal inputs. After the PGA, the signal is digitized by the sigma-delta
modulator. The digital filter notch frequency may be adjusted from 10Hz to 1kHz,
which allows various input bandwidths.
To achieve this high accuracy, the AD771X family has four different internal
calibration modes, including system and background calibration. All of these
1
3
functions are controlled via a serial interface. A benefit of this serial interface is that
the AD771X-family fits into a 24-pin package, giving a small footprint for the high
level of integration. All of the parts except the AD7713 and AD7714 can operate on
either a single +5V or dual ±5V supplies. The AD7713 is designed exclusively for
single supply (+5V) operation. The AD7714 is the newest member of the family and
is designed for either single +3V (AD7714-3) or single +5V (AD7714-5) low power
applications. The AD771X family has <0.0015% non-linearity.
THE AD771X-SERIES PROVIDES
A HIGH LEVEL OF INTEGRATION IN A 24-PIN PACKAGE
Figure 3.16
KEY FEATURES OF THE AD7710
0.0015% Nonlinearity
Two Channels with Differential Inputs
Programmable Gain Amplifier (G = 1 to 128)
Programmable Low Pass Filter
System or Self-Calibration Options
Single or Dual 5V Supply Operation
Microcontroller Serial Interface
Figure 3.17
1
4
The AD7710, AD7711, AD7712, and AD7713 have identical structures of PGA,
sigma-delta modulator, and serial interface. Their main differences are in their
input configurations. The AD7710 has two low level differential inputs, the AD7711
two low level differential inputs with excitation current sources which make it ideal
for RTD applications, the AD7712 has one low level differential input and a single
ended high level input that can accommodate signals of up to four times the
reference voltage, and the AD7713 is designed for loop-powered applications where
power dissipation is important. The AD7713 consumes only 3.5mW of power from a
single +5V supply.
The AD7714 is designed for either +3V (AD7714-3) or +5V (AD7714-5) single-supply,
low power applications. It has a buffer between the multiplexer and the PGA which
can be enabled or bypassed using a control line. When the buffer is active, it isolates
the analog inputs from the transient currents and variable impedance of the
switched-capacitor PGA.
SUMMARY TABLE OF AD771X DIFFERENCES
AD7710:
2-Channel Low-Level Differential Inputs
AD7711:
1-Channel Low-Level Differential Input
1-Channel Low-Level Single-Ended Input
Excitation Current Sources for 3 or 4-Wire RTDs
AD7712:
1-Channel Low-Level Differential Input
1-Channel High-Level Single-Ended Input
AD7713:
2-Channel Low-Level Differential Inputs
1-Channel High-Level Single-Ended Input
Excitation Current Sources for 3 or 4-Wire RTDs
Single 5V Operation Only
Low Power (3.5mW)
No Internal Reference
AD7714:
3-Channel Low-Level Differential Inputs or 5-
Channel Pseudo-Differential Inputs
Single +3V (AD7714-3) or Single +5V (AD7714-5)
Low Power (1.5mW: AD7714-3)
No Internal Reference
Figure 3.18
Because of the differences in analog interfaces, each device is best suited to a
particular sensor or system application. In other words, the sensor and the system
requirements (i.e. type of sensor, single versus dual supply, power consumption, etc.)
determine which converter should be used. Figure 3.19 lists the converters, and the
sensors and applications to which they are best suited.
1
5
AD771X APPLICATIONS
AD7710:
Weigh Scales
Thermocouples
Chromatography
Strain Gauge
AD7711:
RTD Temperature Measurement
AD7712:
Smart Transmitters
Process Control
AD7713:
Loop-Powered Smart Transmitters
RTD Temperature Measurement
Process Control
Portable Industrial Instruments
AD7714:
Single +3V Supply Applications
Portable Industrial Instruments
Portable Weigh Scales
Figure 3.19
Although the AD7714 is often used as an example, the following discussion applies
to all the converters in the family, with some minor exceptions. The basic AD7714
ADC (see Figure 3.20) is a switched capacitor sigma-delta converter which operates
as has previously been discussed in this section. The signals on the input channels
pass through a switching matrix (multiplexer) and into a bypassable buffer. The
buffer (available only in the AD7714) allows the input signals to be isolated from the
PGA switching transients and variable impedance (PGA operation will be described
shortly). The PGA gain is programmable from 1 to 128, thereby allowing low level
signals to be converted without the need for external amplification.
1
6
AD7714 SINGLE-SUPPLY MEASUREMENT ADC
Figure 3.20
The functional block diagram of the AD7714 shows the PGA as separate from the
sigma-delta modulator. In fact, it is part of the sigma-delta integrator (see Figure
3.21). The differential signal input charges C2, which is then discharged into the
integrator summing node. This is done by closing S1 and S2, and then, after opening
them, closing S3 and S4. When the PGA has a gain of 1 this happens once per cycle
of the basic 19.2kHz clock, but for gains of 2, 4, and 8 respectively it happens 2, 4, or
8 times per cycle. The integrator charge is balanced by switching charge in the same
way from the reference into C1, and thence to the integrator summing node. The
polarity of reference switched depends on the state of the comparator output.
1
7
THE AD7714 - MODULATOR INCLUDES A PGA FUNCTION
Figure 3.21
At a gain of 8, the sampling rate is 153.6kHz. Higher switching rates than this
would not allow C2 sufficient time to charge, so for PGA gains greater than 8, the
value of the reference capacitor, C1, is reduced, rather than the sampling rate being
increased. Each time C1 is halved the gain of the system is doubled. The original
value of C1 for gains of 1-8 is about 7pF in the AD7714 and 20pF for the other
members of the AD771X family.
The internal digital filter has the sinc-cubed response illustrated in Figure 3.22. The
first notch in the filter response is programmable according to the formula:
f notch f clkin128 1Decimal Value of Digital Code= ??? ?????? ??? ,
where fclkin is normally either 2.4576MHz or 1MHz for the AD7714. The decimal
value of the digital code in the above equation is loaded into the appropriate register
in the AD7714. The master clock fclkin frequency of 2.4576MHz is chosen because
50Hz and 60Hz may be obtained by direct division as well as the popular
communications frequencies of 19.2kHz and 9.6kHz.
1
8
AD7714 DIGITAL FILTER FREQUENCY RESPONSE
Figure 3.22
The first notch frequency is 3.82 times the -3 dB frequency, so the notch frequency
must be chosen so that the maximum signal frequency falls within the filter
passband.
The lower the notch frequency, the lower the noise bandwidth, and therefore the
higher the effective resolution of the converter. Moreover, the PGA gain will also set
limits on the achievable resolution. With a 2.5V span, 1 LSB in a 24-bit system is
only 150nV - with a gain of 128 it is 1.2nV!
As is evident from their pipeline architecture, sigma-delta ADCs have a conversion
time which is related to the bandwidth of the digital filter:- the narrower the
bandwidth, the longer the conversion. For a 10Hz notch frequency, the AD7714 has
a 10Hz output data rate.
When the input to a sigma-delta ADC changes by a large step, the entire digital
filter must fill with the new data before the output becomes valid, which is a slow
process. This is why sigma-delta ADCs are sometimes said to be unsuitable for
multi-channel multiplexed systems - they are not, but the time taken to change
channels can be inconvenient. In the case of the AD771X-series, four conversions
must take place after a channel change before the output data is again valid (Figure
3.23). The SYNC input pin resets the digital filter, and if it used, data is valid on the
third output afterwards, saving one conversion cycle (when the internal multiplexer
is switched, the SYNC is automatically operated). The SYNC input also allows
several AD771X ADCs to be synchronized.
1
9
THE RATE OF CONVERSION AND
SETTLING TIME DEPENDS ON THE FILTER SETTING
Figure 3.23
Although the AD771X sigma-delta ADCs are 24-bit devices, it is not possible to
obtain 24 bits of useful resolution from a single sample because internal ADC noise
limits the accuracy of the conversion. We thus introduce the concept of "Effective
Resolution," or "Effective Number of Bits," ENOB. This is a measure of the useful
signal-noise ratio of an ADC.
Noise in the ADC is generated by unwanted signal coupling and by components such
as resistors and active devices. There is also intrinsic quantization noise which is
inescapably linked to the analog-digital conversion process. As discussed in the first
part of this section, sigma-delta ADCs use special techniques to shape their
quantization noise and thus reduce their oversampling ratio for a given ENOB, but
they cannot eliminate quantization noise entirely.
In an ideal noise-free ADC, it is possible to position a dc input signal so that the
ADC digital output is always the same code from sample to sample. There is no
quantization noise present, because only one code is being exercised. In a real-world
high resolution ADC, however, there are internal noise sources which can cause the
output code to change from sample to sample for a constant-value dc input signal.
Figure 3.24 shows the comparison between an ideal ADC and an one which has
internal noise. The results are plotted as a histogram, where the vertical axis
represents the number of occurrences of each code out of the total number of 5000
samples used in this example. In the ideal ADC, all 5000 samples result in the same
output code. In the practical ADC, however, internal noise generally results in a
distribution of codes, centered around the primary code. In most cases, the noise is
Gaussian, and a normal distribution can be fitted to the points on the histogram.
The standard deviation of this distribution, sigma, represents the rms value of the
sum of all internal noise sources reflected to the ADC output, measured in LSBs.
This of course assumes a noise-free input. The rms value in LSBs can be converted
easily to an effective rms voltage noise.
2
0
HISTOGRAM SHOWS THE EFFECT OF
INTERNAL ADC NOISE FOR A DC INPUT SIGNAL
Figure 3.24
The signal-to-noise ratio can then be computed by dividing the full scale ADC input
range by the rms noise computed from the histogram. The full scale input range for
the AD771X-series is equal to twice the reference voltage divided by the gain of the
PGA, and the equation for calculating the effective resolution in bits is given by:
Effective Resolution log2 2 VREFGAIN 1RMS NOISE= × ???? ???
DETERMINING EFFECTIVE RESOLUTION
Figure 3.25
Figure 3.26 shows how RMS noise in an AD7714 varies with gain and notch
frequency. Figure 3.27 gives the same results in terms of effective resolution, or
ENOB using the previous equation. The effective output noise comes from two
sources. the first is the electrical noise in the semiconductor devices used in the
implementation of the ADC front end and the modulator (device noise). Secondly,
when the analog input signal is converted into the digital domain, quantization
noise is added.
2
1
The device noise is at a low level, and is largely independent of frequency. The
quantization noise starts at an even lower level, but rises rapidly with increasing
frequency to become the dominant noise source. Consequently, lower filter notch
settings (below 100Hz approximately for fclkin = 2.4576MHz tend to be device-noise
dominated, while higher notch settings are dominated by quantization noise.
Reducing the filter notch and cutoff frequency in the quantization-noise dominated
region results in a more dramatic improvement in noise performance than it does in
the device-noise dominated region. Furthermore, quantization noise is added after
the PGA, so effective resolution is largely independent of gain for the higher filter
notch frequencies. Meanwhile, device noise is added in the PGA, and therefore
effective resolution suffers a little at high gains for lower notch frequencies.
Additionally, in the device-noise dominated region, the output noise (in μV) is
largely independent of reference voltage, while in the quantization-noise dominated
region, the noise is proportional to the value of the reference.
NOISE VARIES AS A FUNCTION
OF GAIN AND FILTER CUTOFF FREQUENCY
(AD7714-5, UNBUFFERED MODE, CLOCK = 2.4576 MHz)
Figure 3.26
EFFECTIVE RESOLUTION VERSUS
GAIN AND FIRST NOTCH FREQUENCY
(AD7714-5, UNBUFFERED MODE, CLOCK = 2.4576 MHz)
Figure 3.27
2
2
It is important to distinguish between RMS and peak-to-peak noise. Noise in a
sigma-delta ADC has a Gaussian (or near Gaussian) distribution. This means that if
one waits long enough, any value of peak noise will eventually occur, and it is not
possible to write a specification absolutely prohibiting a specified value of noise
peak. For practical purposes, the peak-to-peak noise is defined as 6.6 times the RMS
noise, since such peaks occur less than 0.1% of the time. The noise specified in the
ENOB table in Figure 3.27 is expressed in RMS terms. If a figure for "noise-free"
code resolution is required, it will be approximately 3-bits worse: 20-bits ENOB
becomes 17-bits noise-free code, etc. Since most applications are concerned with
noise power, however, the RMS ENOB figure is the more commonly used.
This does not mean that the original 24-bit resolution has no value, however.
Additional external filtering, to narrower bandwidths than the internal filter, can
further improve the resolution and ENOB at the expense of longer conversion times.
The histogram approach using a large number of samples can also be used to more
accurately define the input signal.
ESTIMATING NOISE-FREE CODE RESOLUTION
Determined Using Peak-to-Peak Noise
Output RMS Noise 6.6 = Peak-to-Peak Noise
Factor of 6.6 is Approximately Equal to 3 bits:
log2 (6.6) = 2.72
Therefore, subtract 3 bits from Effective Resolution Given in
Figure 3.27 to Determine Noise Free Code Resolution
Figure 3.28
The results in Figures 3.27 and 3.28 assume the use of a low noise, heavily
decoupled external reference and a noise-free analog input. Noisy inputs (and the
reference is an input) reduce the effective resolution. For this reason, careful
attention must be paid to external noise sources. Figure 3.29 lists aspects of board
layout which may affect system noise, and hence the ENOB of the AD771X-series.
2
3
OPTIMIZING NOISE PERFORMANCE
Pay Attention to Layout!
Use Ground Planes
Keep Analog PCB Tracks Short
Interface Directly with Transducer
Use Low Noise Amplifiers (AD797, OP-213, OP-177, AD707)
(Only if Required)
Connect Analog and Digital Grounds of Converters Together
at the Device, and Connect them to Analog Ground Plane
Route Digital PCB Tracks Clear of Analog Tracks
Filter Signal and Reference Inputs
Minimize Reference Noise
The Evaluation Board is an Example of Good Layout
Figure 3.29
The AD771X-series is designed to interface directly with most transducers without
the need for external buffering or amplification. If external amplifiers are used,
however, low noise devices such as the OP-213 and AD797 should be chosen. To
determine if external amplifiers will lower the AD771X system resolution, the total
additional noise (in the bandwidth 0.1 Hz to the cutoff frequency set in the AD771X)
should be calculated and compared with the RMS noise figures given in Figure 3.26.
(Uncorrelated noise adds by root sum of squares, so if the additional noise is <50% of
the AD7710 noise, it may be ignored; but if it exceeds this level, its effect on system
performance must be studied carefully.)
An external filter on the input of the AD771X-series can improve its noise
performance, because the modulator does not reject noise at integer multiples of the
sampling frequency. This means that there are frequency bands ±f3dB wide (f3dB is
the cutoff frequency of the internal digital filter) where noise passes unattenuated to
the output. However, due to the AD771X high oversampling ratio, these bands
occupy only a small fraction of the spectrum, and most broadband noise is filtered.
The internal analog front end provides some filtering at these frequencies (the
attenuation at 19.2kHz is approximately 70dB), but high level wideband noise can
degrade system ENOB. A simple external RC low-pass filter is generally sufficient to
minimize the effects of this noise, but the resistor and capacitor must be carefully
chosen so that the gain accuracy of the AD771X is not affected. If the AD7714 is
used in the buffered mode (i.e. the internal buffer is active), this restriction does not
apply.
2
4
INPUT FILTER HELPS REDUCE WIDEBAND NOISE
Figure 3.30
A simplified model of the analog input of the AD7714 in the unbuffered mode is
shown in Figure 3.31 (The AD7710, AD7711, AD7712, and AD7713 have similar
structures). It consists of a resistor of approximately 7kohm (input multiplexer on-
resistance) connected to the input terminal and to an analog switch which switches a
7pF sampling capacitor between the resistor and ground, with a mark-space ratio of
50%. The switching frequency depends on fclkin and the gain which is being used:
with a gain of unity and the standard clock frequency of 2.4576MHz, the switching
frequency is 19.2kHz, and at gains of 2, 4, and 8 or more it is 38.4, 76.8, and
153.6kHz respectively.
If the converter is working to an accuracy of 20-bits, the capacitor must charge with
an accuracy of 20-bits. The input RC time constant due to the switch on-resistance
(7kohm) and the sampling capacitor (7pF) is 49ns. If the charge is to achieve 20-bit
accuracy, it must charge for at least 14x the time constant, or 686ns. Any external
resistor in series with the input will increase the time constant, and the chart in
Figure 3.31 shows acceptable values of series resistance necessary to maintain 20-
bit performance.
To determine the minimum charge time for 20-bit performance with an external
resistance Rext we use the equation:
Minimum Charge Time = 14(Rext + 7kohm) x 7pF
The minimum charge time must be less than half the period of the switching signal
used (it has a 50% duty cycle). The fastest switching frequency with the standard
2.4576MHz clock is 153.6kHz (for a gain of 8 or greater), and half of that clock
period is 3.3μs, which allows a maximum Rext of 26.8kohm. At lower gains Rext may
be larger.
2
5
AD7714 ANALOG INPUT STRUCTURE
(UNBUFFERED MODE)
Figure 3.31
It is not practical to use Rext in conjunction with a capacitor to ground from the
input pin of the AD7710, AD7711, AD7712, or AD7713 (or the AD7714 operating in
the unbuffered mode) to make an anti-aliasing filter (with a cutoff frequency less
than one-half the input sampling frequency), unless the capacitor is dramatically
larger than the 7pF Cint. This is because Cint is discharged on every sampling clock
cycle and will recharge from the filter capacitor. Therefore, either the filter capacitor
must be so large that charging Cint from it changes its voltage by less than an LSB
at 20-bits (i.e. it is larger than 7μF), or the time constant RextCext must be short
enough for Cext to recharge before the next clock cycle - in which case the cutoff
frequency due to Rext and Cext is not low enough to make an anti-aliasing filter
with respect to the sampling frequency. There may, however, be some benefit in
such a filter if there is input noise at high frequencies. The data sheets for the
AD771X-series contain tables which give the allowable external capacitor and
resistor values as a function of PGA gain for 16-bit and 20-bit gain accuracy (see
Figure 3.32).
Note that if an external Rext and Cext are used, the capacitor type must have low
non-linearities and dielectric absorption. Film types such as polystyrene or
polypropylene are recommended.
2
6
AD7714 EXTERNAL FILTER RESTRICTIONS ON R AND C FOR
NO 20-BIT GAIN ERROR (UNBUFFERED MODE ONLY)
Figure 3.32
The advantage of the AD7714 operating in the buffered mode is that a true input
antialiasing filter can be used without affecting the gain accuracy. The penalty is
only a slight increase in noise (approximately 10%) and a small reduction in input
common-mode voltage range. If the value of the series resistor is large, the effects of
the input bias current must be considered, but this error can be removed using the
calibration modes.
Some successive approximation and subranging ADCs draw large transient currents
at their analog and reference inputs which load their respective drive circuitry and
cause errors. Often, special drive amplifiers with low output impedance at
frequencies well above the conversion clock frequency are necessary to avoid this
problem, but these problems do not occur with the very small transient loads of the
AD771X devices. The oscilloscope photograph in Figure 3.33 shows the transient
current in an AD7710. It was taken with a 1kohm resistor in series with the input to
measure the change in current. This circuit produces a 15mV spike of less than 1μs
duration. The corresponding peak pulse current is only 15μA, which permits the use
of quite high impedance signal sources with no risk of degrading the ENOB. As
discussed earlier, the AD7714 operating in the buffered mode has no significant
transients on its analog input.
2
7
INPUT TRANSIENT LOADING IS
MINIMAL IN THE AD77XX FAMILY
Figure 3.33
The AD771X family was designed to simplify transducer interfacing. Many types of
transducers can be connected directly to the input of one of the AD771X family
without additional circuitry, but some care is necessary to achieve the best possible
accuracy:- noise needs to be minimized (a simple capacitor across a resistive sensor
may be all the filtering that is needed, but this must be checked - noise is
particularly important, because noise cannot be removed by the system calibration
which eliminates gain and offset errors); transducer source impedance may affect
charge times (as mentioned above); and bias currents flowing in high impedance
transducers may cause errors, although these can be removed by system calibration.
In general, system calibration can remove most dc errors in systems using the
AD771X family.
2
8
TRANSDUCER CONNECTION CONSIDERATIONS
Filter Noisy Signals
Use Shielded, Twisted Pair Cable (Shield Grounded at
AGND/DGND Connection Point at ADC, floating at transducer)
DC Leakage (bias) Current = 10pA can cause offset with
Rsource
This causes drift over temperature
To Maintain Accuracy:
Minimize Rsource
Use Differential inputs and balance Rsource
Use system calibration techniques
Figure 3.34
Circuitry connected to transducers must generally be protected against over-voltage
from ESD, noise pickup, or accidental shorts. If signals are likely to go outside the
positive or negative supplies, some form of clamp is necessary to keep them within
them. Figure 3.35 shows a suitable circuit for protecting AD771X devices. The
AD7710 has internal ESD protection diodes between the input and both supplies
which conduct when the input exceeds either supply by more than about 0.6V.
Excessive current in these diodes will vaporize metal tracks on the chip and damage
the circuit, so an external resistor, Rp, is necessary to limit current to a safe 5mA
during over-voltage events. Rp may be determined by a simple calculation:
Rp
Vmax Vsupply
5mA=
?
Rp will contribute noise to the system ( the basic Johnson noise equation applies:
en kTBR p= 4
where k is Boltzmann's Constant, T is the absolute temperature and B is the
bandwidth). If the noise due to Rp is too high, Rp can be reduced if external Schottky
diodes are used in addition to the diodes on the chip.
2
9
INPUT OVERVOLTAGE PROTECTION
Figure 3.35
There are no special requirements for these Schottky diodes, as long as they have
low leakage current and can handle the necessary fault current levels while
maintaining a low turn-on voltage.
As important as the analog signal input is the reference input. Figure 3.36 shows a
simplified model of the reference input, which is very similar to that of the analog
input (with the exception of the AD7714 operating in the buffered mode). The series
resistor is 5kohm, and the value of the capacitor depends on the gain setting and the
particular device. For gains of 1-8, the capacitor is approximately 7pF for the
AD7714. Above 8, the capacitor's value is halved for each doubling of gain. The value
of the capacitor (G = 1-8) for other members of the AD771X series is 20pF.
REFERENCE VOLTAGE CONSIDERATIONS
Figure 3.36
3
0
An important consideration in choosing a reference for the AD771X-series is noise.
Many references have output noise which exceeds that of the AD771X and cause
reduced accuracy. Filtering may help in such cases, but a low noise reference should
be selected wherever possible.
Although the AD7710, AD7711, and AD7712 have internal +2.5V references which
may be connected to their positive reference input, their use will degrade the
effective resolution of the ADCs by approximately 1 bit for filter cut-off frequencies
of 60Hz or less. The noise calculations using the AD7710 internal reference are
shown in Figure 3.37. For optimum noise performance, a low noise external
reference such as the AD780 should be used as shown in Figure 3.38.
INTERNAL REFERENCE VOLTAGE NOISE
CONSIDERATIONS FOR AD7710, AD7711, AD7712 ADCs
Figure 3.37
USE A LOW NOISE EXTERNAL REFERENCE
FOR OPTIMUM NOISE PERFORMANCE AND RESOLUTION
Figure 3.38
3
1
The AD780 2.5V reference has noise of 4μV p-p in the range 0.1 to 10Hz. This is
equivalent to 0.606μV rms (obtained by dividing the peak-to-peak value by 6.6).
This gives 0.31μV rms noise in the 2.62Hz bandwidth associated with a 10Hz update
rate. This is negligible compared to the AD7710 inherent noise of 1.7μV rms (G = 1).
With output rates of 1kHz or more, and cutoff frequency of 262Hz, the noise of the
AD780 may be reduced by 50% if a 0.1μF capacitor is connected to its output (unlike
many IC voltage references, the AD780 is stable with all values of capacitive load).
CALCULATING REFERENCE NOISE CONTRIBUTION
Figure 3.39
The AD780 is also a suitable reference for the AD7714 ADC, whose noise with a
10Hz update rate (G = 1, Vsupply = +5V) is 1.0μV rms. When the AD7714 is
operating on a +3V supply, it requires a low-noise 1.25V reference, and the AD589 is
a suitable choice.
When the AD771X-series ADCs are operated at higher output rates and higher
input bandwidths, the ADC noise is significantly higher, and less effective resolution
is required. This allows the use of higher noise, lower power references such as the
REF192 (25μV p-p noise, 0.1 to 10Hz) which only requires 45μA of quiescent current,
compared to 0.75mA for the AD780.
Regardless of the reference selected, it should be properly decoupled in order to act
as a charge reservoir to transient load currents as well as a filter for wideband noise.
This implies that the reference must be stable under capacitive loads, which is not
necessarily the case in all references. In fact, some references actually require an
external decoupling capacitor in order to maintain stability. Regardless of the
reference selected, the data sheet should be carefully examined with respect to
output capacitive loading. Further information on applying voltage references can be
obtained in References 5, 6, and 7.
3
2
LOW VOLTAGE REFERENCE SUMMARY
Figure 3.40
DC errors also affect conversion accuracy, but AD771X devices can calibrate
themselves to correct dc errors. The AD7710, AD7711, AD7712, and AD7713 have
four different calibration modes. These are summarized in Figure 3.41 and comprise
Self Calibration, System Calibration, System-Offset Calibration, and Background
Calibration. Each calibration cycle contains two conversions, one each for zero-scale
and for full-scale calibration. The calibration modes for the AD7714 are similar,
except that in the Background-Calibration Mode, only zero-scale is calibrated.
AD771X OFFERS 4 CALIBRATION OPTIONS
Figure 3.41
To initiate a calibration cycle, the appropriate code must be sent to the control
register. After the code is sent, the AD771X automatically conducts the entire
operation, and clears the control register of the calibration command so that a
separate command to stop calibration is not necessary. Since the filter in the sigma-
delta converter must purge itself of its previous result for four output update cycles
whenever the input sees a full-scale step the total calibration operation takes nine
such cycles.
Self Calibration removes errors in an AD771X by connecting the input to ground and
performing a conversion, and then connecting the input to Vref and performing
another. The results of these conversions are used to calibrate the device.
3
3
Background Calibration is a variation of Self Calibration. The only difference is that
when an AD771X is placed in Background Calibration mode, it continually
calibrates itself at regular intervals without further instructions. This ensures that
the AD771X remains calibrated regardless of drift. The Background Calibration
cycle alternates calibration conversions with signal conversions: zero
calibrate/convert signal/full-scale calibrate/convert signal/zero calibrate/etc. This
provides continuous calibration but reduces the output data rate by a factor of six.
Background Calibration for the AD7714 only calibrates zero-scale.
System Calibration is intended to calibrate all the elements prior to the ADC which
may contribute to system errors, as well as the ADC itself. (For example an
instrumentation amplifier introduces errors into a system due to its own offset, drift
and gain error. These errors can be removed by System Calibration.) However,
System Calibration requires additional analog switches to connect system inputs to
ground and a reference as well as to the original signal source. The first step in
System Calibration requires external grounding of the system input terminal to
calibrate out offsets. The second step requires that the input be connected to a
reference, which calibrates gain error at full-scale. The System Calibration cycle
requires the sending of two separate instructions to the control register as well as
control of the analog switches at the system input. It must be repeated regularly to
correct for drift with time and temperature.
The final calibration mode is System-Offset Calibration. This calibrates system
offsets, and the AD771X gain. Again, it requires external analog switches at the
system input, and separate instructions for zero and gain calibration. For the first
cycle, the system input is connected to ground and the AD771X calibrates for system
offsets. During the second cycle, the ADC input is connected to the reference for
ADC gain calibration.
CALIBRATION ISSUES
Figure 3.42
3
4
When calibration is complete, DRDY goes low - but it does not necessarily go high as
soon as the calibration command is sent to the ADC, there may be a delay of up to
one output data cycle before it does so. Controllers should therefore look for a 0 to 1
transition, rather than the presence of a 0, on DRDY to signal the completion of a
calibration after it has been commanded.
Calibration is crucial to achieving the rated accuracy of AD771X devices and should
be performed immediately after power-up and repeated regularly. A 1.25μV/°C
temperature coefficient of input offset and a 2°C temperature change causes an LSB
of error in a 20-bit 2.5V system. Any reference drift adds to the error. Frequent
calibration ensures that temperature changes do not degrade the accuracy of
conversions.
CALIBRATE OFTEN TO MAINTAIN ACCURACY
Temperature Drift can cause errors
Unipolar offset drift of 2.5 V is 1 LSB in a 20 bit system
(2.5V full-scale)
Reference voltage drift adds to this error
Calibration can remove gain errors created by input filters
Therefore, to minimize errors, calibrate often.
Always calibrate on power-up!
Calibration coefficients can be manually adjusted
Figure 3.43
When the AD771X executes a calibration cycle, it saves two coefficients in internal
registers. One register stores the full scale calibration coefficient, FSC, and the other
stores the zero scale calibration coefficient, ZSC. Adjusting the calibration
coefficients manually may be useful in some applications. For example, in a weigh
scale application it may be necessary to insert an offset to account for a fixed weight.
It is possible to read from and write to the calibration registers of members of the
AD771X family, making adjustment of calibration coefficients a straightforward
task. Details of this procedure are given in References 4 and 8.
A typical application of the AD7710 is in a weigh scale (Figure 3.44). These generally
use a resistive bridge as their sensing element and require resolution of at least
16-bits and often more. The AD7710 dramatically simplifies the design of such a
system: the bridge is connected directly to its differential inputs, making an external
instrumentation amplifier unnecessary. The excitation for the bridge, and the
reference for the AD7710, are provided by an AD780, whose low noise helps to
preserve the system ENOB. Because the system bandwidth is limited (both by the
conversion rate selected and the filter capacitors on the bridge) the ENOB
achievable is quite high (approximately 20-bits) but the conversion (and output data)
rate is rather low at 10Hz.
3
5
WEIGH SCALE APPLICATION USING THE AD7710
Figure 3.44
The converters in the AD771X family all have serial interfaces, which are
described in greater detail in the data sheet. They have control registers that control
all their operations. Changing the PGA gain, starting a calibration, and changing
the filter parameters are all accomplished by writing to the appropriate register. On
the other hand, data can be read either as a 16-bit or a 24-bit operation - one of the
bits in the control register controls the size of the data word. The DRDY output
indicates when a conversion is complete and valid data is available in the output
register.
Figure 3.45 shows an isolated 4-wire interface to the AD7713 using common opto-
isolators. Over 6kV of isolation is possible. The TFS, A0, and SYNC lines are tied
together at the converter to minimize the number of control lines. Tying TFS to AO
causes a write to the device to load data to the control register, and any read
accesses the data register. The only restrictions of this method of control is that the
controller cannot write to the calibration registers and cannot read from the control
register. In many applications these capabilities are unnecessary. Four
opto-isolators carry data and instructions from the controller to the ADC and a fifth,
with a 74HC125 on each side of the isolation barrier, carries data to the controller.
The AD7713 is ideal for this particular application because its low supply current
minimizes the load on the isolated power supply.
3
6
ISOLATED 4-WIRE INTERFACE USING AD7713
Figure 3.45
The AD771X family generally interfaces with some type of microprocessor. Their
data sheet includes circuits and micro-code for interfacing to the 8051 and 68HC11
microcontroller and the ADSP-2103/2105 DSP processor. Figure 3.46 shows how the
AD7714 may be interfaced to the 68HC11 microcontroller. The diagram shows the
minimum (three-wire) interface with CS on the AD7714 hard-wired low. In this
scheme, the DRDY bit of the AD7714 Communications Register is monitored to
determine when the Data Register is updated. Other schemes are described in the
AD7714 data sheet.
3
7
AD7714 TO 68HC11 MICROCONTROLLER INTERFACE
Figure 3.46
Interfacing to the ADSP-2103/2105 is also relatively straightforward. The DRDY bit
of the Communications Register is again monitored to determine when the Data
Register in the AD7714 is updated.
3
8
AD7714 TO ADSP-2103/2105 DSP INTERFACE
Figure 3.47
The AD771X sigma-delta converters are powerful tools for building high accuracy
systems. Every one of them combines high resolution, system calibration, a
programmable gain amplifier, and high impedance differential inputs with great
ease of design. Their adjustable digital filters provides flexibility in the choice of
data rates and resolution and their serial interface minimizes their pin count, so
that they fit in a 24-pin skinny DIP package, providing a high degree of functionality
in a small space.
The AD7714 is especially suitable for low power applications. Figure 3.48 shows the
total supply current required as a function of supply voltage for two clock
frequencies: 2.4576MHz and 1MHz. These data are for an external clock with the
AD7714 operating in the unbuffered mode. Figure 3.48 illustrates an important
point which is applicable to a large number of low power data converters - the total
power dissipation is a function of the clock frequency! Make sure to check the data
sheet carefully for this dependency when estimating the total power requirement.
The power dissipation of older, higher-power, bipolar data converters was generally
much less sensitive to clock frequency than the modern low-power CMOS designs.
3
9
AD7714 TOTAL SUPPLY CURRENT
(EXTERNAL OSCILLATOR)
Figure 3.48
An area where the low power, single supply, three wire interface capabilities of the
AD7714 is of benefit is in smart transmitters (Figure 3.49). The entire smart
transmitter must operate from the 4mA to 20mA loop. Tolerances in the loop mean
that the amount of current available to power the entire transmitter is as low as
3.5mA. The AD7714 consumes only 500μA, leaving 3mA available for the rest of the
transmitter. Not shown in Figure 3.49 is the isolated power source required to power
the front end circuits, including the AD7714.
SMART TRANSMITTER USING AD7714 OPERATES
ON 4mA TO 20mA LOOP CURRENT
Figure 3.49
4
0
REFERENCES
1. S .A.Jantzi, M.Sn e lgr o v e & P.F.Fe r g uso n Jr ., A 4t h - Or d e r B and pass
Si gm a- De l t a Mo du l ato r , IEEE Journal of Solid State Circuits,
Vol. 38, No. 3, March 1993, pp.282-291.
2. System Applications Guide, Analog Devices, Inc., 1993, Section 14.
3. Mixed Signal Design Seminar, Analog Devices, Inc., 1991, Section 6.
4. AD7710, AD7711, AD7712, AD7713, AD7714 Data Sheets,
Analog Devices.
5. Walt Jung, Getting the Most from IC Voltage References,
Analog Dialogue, 28-1, 1994, pp. 13-21.
6. Walt Jung, Build an Ultra-Low-Noise Voltage Reference, Electronic
Design Analog Applications Issue, June 24, 1993.
7. Linear Design Seminar, Analog Devices, Inc., 1995, Section 8.
8. System Applications Guide, Analog Devices, Inc., 1993, Section 6.