Problem Set 2 BE.462J/3.962J
Biodegradable Solid Polymers Spring 2003
Issued: Day 4
Due: Day 5
(20 pts total)
1. An early study in the development of peptide-presenting biomaterials showed that polymer
surfaces bearing RGD peptides at a density equivalent to ~10
5
peptides per each cell was sufficient
to promote cell attachment, spreading, and subsequent cell growth. In contrast, when whole
fibronectin protein was adsorbed to polymer surfaces, it was found that many more copies of the
intact protein were needed per unit area to obtain similar responses from cells. Explain this result.
How should the binding of cell integrin receptors to a short RGD peptide compare with binding to
native fibronectin?
2. In the article by Schense et al., Figures 1 and 2 show that different adhesion peptides
incorporated into a natural biopolymer matrix (a fibrin fiber network) induce different degrees of
neurite outgrowth from neuronal cells, even when conjugated to the matrix at the same total
densities. Provide 2 physico-chemical reasons to explain how different peptides can provide
different responses.
3. Compare and contrast the erosion characteristics expected for a device to be used in vivo that is
fabricated from a polyesteramide vs. the characteristics of the same device fabricated using a
polyanhydride.
4. Design of an artificial artery. (10 pts) Shown below is a simplified schematic of the structure of
an artery .The two primary features of an artery are the endothelial cell lining on the interior lumen of
the vessel (contacting blood flow) and the smooth muscle cell layer surrounding the vessel, which
can provide contractile force to support the mechanical integrity of vessels under blood pressure.
Artificial blood vessels (vascular grafts) have been studied for many years and are in extensive
clinical use, however, the simple synthetic grafts typically used (e.g. Dacron or
poly(tetrafluoroethylene) (Teflon) polymer tubes) are not safe for small-diameter blood vessel
replacement (vessel diameters < 6 mm) and show loss of patentcy, due to rapid occlusion of the
grafts by depositing platelets. (Patentcy is the term used to describe an open, viable vessel.) Read
the attached brief discussion of approaches to blood vessel engineering, and then answer the design
questions below for an improved small-diameter artificial vessel based on the biomaterials design
principles discussed in class so far and the prototype
design sketched below: The 'prototype' is to be sutured to the ends of natural blood vessels to
replace diseased/blocked sections of vasculature.
BE.462J/3.962J PS 1 1 of 2
a. Describe the first events that will occur at the surface of a hydrophobic polymer like
poly(tetrafluoroethylene) (structure shown below) when it is implanted as a vascular graft,
and how these events could lead to graft occlusion.
b. Would you choose a degradable or non-degradable polymer for the artificial vessel
scaffolding? Explain your choice. (5 pt.s extra credit: describe what polymer in particular
you would choose and motivate why you’d make that choice.)
c. One strategy that could be applied to this artificial vessel would be to implant the polymer
and seek to have native endothelial cells and smooth muscle cells from the adjacent
native vessels migrate into the polymer scaffold to recreate the native inner and outer
cellular lining of the graft. Describe a strategy to modify the ‘prototype’ scaffold in order
to promote this process, and outline a preliminary experiment you could use to test the
utility of your approach.
d. Inclusion of adhesion peptides in the inner surface of the artificial vessel could have both
positive and negative effects on patentcy early after implantation- describe one positive
and one negative outcome that could occur, depending on the choice of peptides utilized.
BE.462J/3.962J PS 1 2 of 2